MOREHOUSE MODEL 4215 DUAL CHANNEL UNIT 

 
   
Load Cell Meters
Force Calibration Service (Accredited to Iso Guide 17025) A2LA
Load Cell Meters
Morehouse Cellmite Calibration Solution

 

 

We Offer the following

 

Calibration Grade Load Cells with ASTM E74 lower limits from 2% -8% of capacity click here.

Morehouse Custom Carrying Cases for your load cell system click here

Morehouse Cellmite Calibration Solution

Morehouse Calibration Software Available for download

Morehouse Model 4215 manual

 

Have us set up and calibrate your load cells with the Morehouse Load Cell Meter.   

 

 

 

 

 

Contact Information

E-Mail: hzumbrun@mhforce.com   

Telephone: (717)  843-0081

Fax: (717)  846-4193

 

 

NEW: MOREHOUSE UNCERTAINTY FOR CALIBRATIONS

0 -120,000 LBF  -  .002% of applied

 

NEW 1,000,000 LBF Secondary Standard Calibrated Directly by N.I.S.T with 13 LBF UNCERTAINTY. 

 

 

Morehouse Load Cells Meters

dual channel load cell meter

Load Cell meter with Fully Bipolar Range +/-999,999 Display, 24 bit resolution, Auto Setup for 25 Load Cells

Standard Features:  

  • Fully Bipolar Range +/-999,999 Display

  • 24-Bit Resolution

  • Non-linearity 0.005%

  • 2-line X 20 Character Vacuum Fluorescent Display

  • Auto Load Cell Identification

  • User Input Text Label on Second Line of Display

  • Auto Setup for 25 Load Cells

  • Front Panel Shunt Calibration with Two Selectable Resistors

  • Functions Included: Peak / Valley / Hold / Tracking / Peak Reset

  • Quad Limits Output: Independent, Isolated Solid State Relays, Controls AC or DC Signals

  • Six User-Selectable Filters

  • Tri-state Limit Display: On, Off, Disabled

  • Automatic Display Unit Conversion: Lb, Kg, N Psi, Mpa, Klb, Kn, t

  • D/A Output: 10V std; 5V 

  • Direct Analog Amplifier Output

  • RS485 std.

  • Full Operation and Calibration via RS232

  • Dual Channel

  • 10- Point Linearization is available as an option,

  • OPTIONAL FEATURE - MOREHOUSE SOFTWARE TO ALLOW MODEL 4215 TO BECOME DIRECT READING UNIT IF CALIBRATED IN mV/V (This requires the user to have a laptop with RS232 or USB port and uses coefficients generated from the calibration report to read in direct engineering units of LBF, KGF, or N) Newer systems uses USB cables and RS232 is no longer needed.  This software works on Sensor A only.  On a dual channel unit the software can be used for the calibration standard on Sensor A, while readings may be taken simultaneously on Sensor B (Load B) from the display on the 4215 indicator.