MOREHOUSE DIRECT READING LOAD CELL SYSTEM

 
   
Load Cell Meters
Force Calibration Service (Accredited to Iso Guide 17025) A2LA
Load Cell Meters
Morehouse True Direct Reading Calibration Solution

 

We Offer the following

Calibration Grade Load Cells with ASTM E74 lower limits from 2% -8% of capacity click here.

Morehouse Custom Carrying Cases for your load cell system click here

Morehouse Calibration Systems

Morehouse 4215 Calibration Software Installation Instructions

Morehouse Model 4215 manual

 

Have us set up and calibrate your load cells with the Morehouse Load Cell Meter.   

 

Contact Information

E-Mail: hzumbrun@mhforce.com   

Telephone: (717)  843-0081

Fax: (717)  846-4193

 

 

NEW: MOREHOUSE UNCERTAINTY FOR CALIBRATIONS

0 -120,000 LBF  -  .002% of applied

 

NEW 1,000,000 LBF Secondary Standard Calibrated Directly by N.I.S.T with 13 LBF UNCERTAINTY. 

DIRECT READING LOAD CELL SYSTEM

FOR CALIBRATION OF LOAD CELLS, TESTING MACHINE AND OTHER FORCE SYSTEMS.

DIRECT READING ACCORDING TO ASTM-E74 WHEN USING A COMPUTER INTERFACE WITH MOREHOUSE INDICATOR AND MOREHOUSE CUSTOM SOFTWARE.

ASTM CLASS A LOWER LIMITS BETTER THAN 2% WHEN PAIRED WITH MOREHOUSE ULTRA PRECISION LOAD CELLS

ADVANTAGES OF THE MOREHOUSE 4215 DIRECT READING LOAD CELL SYSTEM ARE:

#1.  THE PROGRAM ELIMINATES THE NEED FOR LOAD TABLES.  (THIS PROGRAM WAS DESIGNED TO USE THE COEFFICIENTS FROM A CALIBRATION REPORT AND APPLY THEM TO THE "LIVE" SIGNAL OF THE 4215 UNIT.

#2.  THE UNITS "AS RECEIVED" CALIBRATION IS THE SAME AS THE UNITS "AS RETURNED" CALIBRATION   (IN MOST CASES THE SYSTEM IS SETUP SO THAT  THE UNIT IS CALIBRATED IN mV/V.  THEN THE NEW CALIBRATION COEFFICIENTS ARE THEN ENTERED USING THE CALIBRATION DATA SUPPLIED BY MOREHOUSE.  THE DATA REPORT ISSUED IS ALWAYS READ IN mV/V)  

#3.  THE SYSTEM IS A TRUE DIRECT READING DEVICE. IT REQUIRES A LAPTOP COMPUTER AND USES COEFFICIENTS FROM ASTM E74 CALIBRATIONS TO GENERATE THE VALUE FOR THE LOAD BEING APPLIED.  THE END USER CAN READ DIRECT ENGINEERING UNITS IN  LBF, KGF and NEWTONS

#4.  MOREHOUSE GAURANTEES THIS SYSTEM TO HAVE A CLASS A LOADING RANGE OF 10% OR BETTER ON ALL MOREHOUSE LOAD CELLS (THE SYSTEM WILL HAVE A BETTER THAN 2% LOADING RANGE WHEN PAIRED WITH MOREHOUSE ULTRA PRECISION LOAD CELLS AND HAVE BETTER THAN 4% LOWER LIMITS WHEN PAIRED WITH MOREHOUSE PRECISION LOAD CELLS) .  MOREHOUSE INSTALLATION INSTRUCTIONS CAN BE FOUND HERE

 Please Click Here for information on other Morehouse Load Cell Systems